High Speed Fabric Doors
Raynor’s RapidCoil RC200 high speed fabric door is designed for small- to medium-interior technology applications up to 12′ wide and 12′ high. The RC200 door is designed for interior environments, providing a high-tech, safe, and aesthetically pleasing door for even the most demanding customers. The RC200 combines our proven control and drive system with our specially modified bead sealing technology for ultra-smooth, ultra-quiet operation. Incorporating Raynor’s control panel, with a variable frequency drive, provides maximum performance, flexibility, and self-diagnostic capabilities.
Every Raynor RapidCoil RC200 commercial high speed fabric door is built for superior performance and includes the features listed below.
Specially modified bead sealing technology prevents air migration better than virtually any other door on the market. Sealing technology also completely seals the opening, providing a perfect barrier against drafts, humidity, noise, dust, and insects. This door is ideal for use in dry and clean room environments.
Specialized two-way breakaway design, with inner side guides, flexes to allow separation when impacted. The re-insertion point, located at the header, allows you to re-insert the curtain into the guides by the simple push of the button. No manual intervention or tools are required.
Cycle Life: RapidCoil doors are designed to perform thousands of cycles per day without wearing parts such as stiffeners, cables, and straps or motor brakes, repair cost, and operational costs are reduced.
The Raynor RapidCoil RC200 high speed fabric door is 27 oz. reinforced PVC vinyl with your choice of 9 colors.
Blue | RAL 5002 | |
Red | RAL 3001 | |
Orange | RAL 2004 | |
Yellow | RAL 1003 | |
White | RAL 9003 | |
Gray | RAL 7038 | |
Green | RAL 6005 | |
Black | RAL 9005 | |
Brown | RAL 8017 |
>>Colors displayed on monitors, mobile devices, and printed materials will vary from the actual vinyl color. Contact your local Raynor Authorized Dealer for color samples.
Door | ||
Mount | Interior | |
Configuration | Single Door | |
Minimum Size | 3′ x 7′ | |
Maximum Size | 12′ x 12′ | |
Operation | By gravitational force with a flexible ballast | |
Opening Speed | Up to speeds of 48 in/sec | |
Closing Speed | 24 in/sec | |
Drive | Left or Right Hand | |
Wind Resistance | Up to 18 MPH operational | |
Electrical | ||
Motor | 1HP or 2HP motor dependent on size of door. Motor is VFD driven, Nema 4, 2 poles without brake. | |
Detectors supplied with standard door | Infrared photocell system, curtain obstruction detector and wireless obstruction detector | |
Control Box | Composite corrosion resistant Nema 4X rated control box as standard | |
Power Supply | Single-phase 110-208-230-Three-phase 460-575 Volt | |
Frequency | 50-60 Hz | |
Curtain | ||
Material | Reinforced PVC vinyl | |
Total Weight | 27 oz./sq. yd. | |
Tensile Strength | 637 x 683 lbs | |
Tear Resistance | 120 x 138 bls | |
Available Colors | Blue RAL 5002 Red RAL 3001 Orange RAL 2004 Yellow RAL 1003 White RAL 9003 Gray RAL 7038 Green RAL 6005 Black RAL 9005 Brown RAL 8017 |
|
Vision | One Vision banner 15″ x door width standard, Individual windows 24″ x 24″ and Bug Screens optional | |
Guides | ||
Side Guides | Structural Channels of 2-1/8″ x 1-3/16″ x 1/8″ galvanized steel | |
Inner Side Guide | Polyethylene (PE-HD) inner section 9/16″ x 9/16″ mounted in 1/32 x 1-1/8 C Channel | |
Side Guide Covers | Standard is galvanized 2-1/8″ x 2-1/2″ in size | |
Color/Finish | Galvanized standard, Powder Coat or 304 Stainless Steel optional | |
Drum | ||
Construction | Steel, diameter 4″ x 0.078″, shafts in steel | |
Enclosures | ||
Hood | Measurement dependent on width of door x headroom of 15-1/2″ | |
Motor Cover | 9-1/8″ x 20″ x 10-1/4″ standard in galvanized | |
Color/Finish | Galvanized standard, Powder Coat or 304 Stainless Steel optional | |
Warranty | ||
5-year unlimited cycle warranty on the drive motor and 5-years on fabric workmanship. 1-year on balance of components. |
Standard Operating Speed:
Opening speed up to 48″/sec, closing speed 24″/sec.
Door Operation:
Gravity driven with flexible soft bottom bag.
Side Guides:
Made of structural channels of 2-1/16″ x 1-1/2″x1/8″ in galvanized steel
(optional powder coat or stainless steel).
Inner Side Guide:
Polyethylene (PE-UHMW 1000); outer section 9/16″ x 9/16″.
Side Guide Covers:
Galvanized steel is standard or optional powder coat or stainless steel covers are available.
Drum:
Steel, diameter 4″ x 0.078″, shafts in steel.
Door Curtain:
Reinforced PVC (27 oz/sq.yd) and continuous sealing, bead, with flexible weighted soft bottom bag design. Available in different colors.
Vision:
15″ vision banner standard. 24″ x 24″ individual windows and bug screens are optional
Door Size:
Raynor RC200 has a maximum door size of 12’x12′. Minimum size of 3’x7′.
Motor:
Standard 1HP at 115V, 208V, 230V, 460V or 575V. Motor is variable frequency driven, NEMA 4, 2 poles without brake.
Gearbox:
Size 50 for a motor of 1HP and gear reduction ratio 1/28.
Detectors:
An infrared photocell installed inside the side guide and detects the presence of a pedestrian or a vehicle. Upon activation, it opens the door immediately and keeps it open as long as the presence is detected. Height of photocell: 6″ from the floor.
A bottom edge detector reverses the door when it hits an obstacle during the closing cycle. This detector is positioned at the bottom part of the curtain.
The bottom edge is referred to as a WDD or Wireless Detector. A wireless detection system consisting of a transmitter in the bottom bag of the door and a receiver in the control box. The system operates according to the “open loop” principle: when the sensor encounters an obstacle, the transmitter leaves the standby mode and send a signal to the receiver that immediately
opens the door.
Power Supply:
Standard single phase 115V, 208V, 230V; three phase 208V, 230V, 460V, 575V. Frequency: 60 Hz. Circuit breakers to be provided by the customer: 10-20A for 1HP.
Optional Egress Systems:
Choose our, fully code compliant, Emergency Egress System or battery backup for added security.
Absolute Encoder:
The absolute encoder replaces the old fashioned, less accurate, mechanical limit switches, for maximum door efficiency and productivity.
Logix Controller: